The Def-7000A defibrillator Monitor is an electronic device that administers and monitors electric shock of pre-set voltage to the heart through the chest wall to restore the heart's normal rhythm during ventricular fibrillation.
Technical specifications
Display
Screen Type: High-resolution display
Screen Size: 7 inches (1 7.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits Delivered Energy
Defibrillator
Waveform: Biphasic
Energy Display: Monitor display indicates both selected and delivered energy
Charge Prompt Type: Voice and visual prompts
Electrode Impedance Measurement Range: 0-250 0hms
AED Mode
AED Function: Auto analyzes and charges x3 with programmable auto energy level selection, screen prompts, and voice prompts
Shockable Rhythms: Ventricular fibrillation, Ventricular tachycardia, QRS complex wave duration
Charge Control: Control the device's front panel, and press the key on the paddle.
Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 Joule
Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on the monitor
ECG Monitoring
Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles
Lead Selection: Displayed on monitor, paddles, l, II, III, AVR, AVL, AVF, V
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor
Heart Rate: 20-300BPM
Heart Rate Alarm: On/Off displayed on monitor, user-selectable
Smart Alarms: Beeper/Voice prompts indicate shockable rhythm
SpO2 Module
Measurement Range: 30-100%, +2% between 80%-90%, others + 5%
Alarm Range: User sets high limit and low limit
Alarm Accuracy: +10% within setting values
Alarm Time Accuracy: Less than 12 sec
Recorder
Paper: 50mm thermal
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay
Printing Method: High-resolution, thermal array print head
Print-out Modes: Manual or automatic, user-configurable
On/Off Control: Front panel and paddle
Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge
Battery
Type: Rechargeable, Ni-MH battery, 12V
Operating Time: For a new, fully charged battery, 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will affect operating time with different functions.
Pacer
The pacer function is optional